FyreWrap® Elite® 1.5 Duct Insulation – Air Distribution System (ADS) Ducts

FyreWrap® Elite® 1.5 Duct Insulation is a single layer flexible duct wrap enclosure for 1- and 2-hour fire-rated air distribution systems (ADS ducts). Typical duct types include smoke control, hazardous exhaust, laboratory chemical fume, stairwell and vestibule pressurization, ventilation, supply/return ducts, commercial dryer exhaust, as well as refuse and linen chutes. This slim, compact design is an alternate to code prescribed fire-rated shafts and results in significant weight, space and labor savings when compared to traditional shafts.

FyreWrap Elite 1.5 Duct Insulation Air Distribution System (ADS) offers the following features:

  • 1- and 2-hour fire-rated enclosure (3 hour available)
  • Alternate to fire-rated shaft
  • Zero clearance to combustibles at all locations on blanket wrap
  • Saves weight, space, labor
  • Thin, lightweight single-layer system
  • High-temperature, biosoluble insulation
  • Durable foil-scrim covering
  • GREENGUARD listed for Microbial Resistance

This flexible, fire protection wrap meets the requirements defined by the Mechanical Code and is an alternative to a traditional fire-rated shaft wall enclosure around ducts. It is used to wrap HVAC ducts, stairwell pressurization ducts and smoke extraction ducts and provide critical fire protection and life safety.

Specifications on various FyreWrap® Duct Insulation systems are available in the Product Resource Center.

arcat fire protection

Material Estimator Tool


Documents.

Safety Data Sheets

FyreWrap® Elite® 1.5 Duct Insulation – Air Distribution System (ADS) Ducts

Product Information Sheet

Certification

Air Distribution System Duct Through Penetration Firestop System‑Horizontal Duct (2 Hour) Test Standard ASTM E814 Design No. UNI PHV 120‑04

Certification

Air Distribution System Duct Through Penetration Firestop System‑Horizontal Duct (3 Hour) Test Standard ASTM E814 Design NO. UNI PF 180‑01

Certification

Air Distribution System Duct Through Penetration Firestop System‑Horizontal Duct (2 Hour) Test Standard ASTM E814 Design No. UNI PHV 120‑03

Certification

Air Distribution System Duct Through Penetration Firestop System‑Vertical Duct (1 Hour) Test Standard ASTM E814 Design No. UNI PV 60‑01

Certification

Air Distribution System Duct Through Penetration Firestop System‑Vertical Duct (2 Hour) Test Standard ASTM E119 Design No. UNI FRD 120‑24

Certification

Air Distribution System Duct Through Penetration Firestop System‑Vertical Duct (2 Hour) Test Standard ASTM E814 Design No. UNI FRD 120‑23

Certification

Air Distribution System Duct Through Penetration Firestop System‑Vertical Duct (2 Hour) Test Standard ISO6944 Design No. UNI FRD 120‑21

Certification

Air Distribution System Duct Through Penetration Firestop System‑Vertical Duct (3 Hour) Test Standard ASTM E814 Design No. UNI PF 180‑02

Certification

Air Distribution System Duct General Installation (2 Hours) Test Standard ISO 6944 Design NO. UNI FRD 120‑01

Certification

Air Distribution System Duct General Installation (2 Hours) Test Standard ISO 6944 Design NO. UNI FRD 120‑15

Certification

Air Distribution System Duct General Installation‑Horizontal Duct (3 Hour) Test Standard ISO 6944 Design NO. UNI DI 180‑01

Certification

Air Distribution System Duct General Installation‑Horizontal Duct (3 Hour) Test Standard ISO 6944 Design NO. UNI DI 180‑02

Product Information Sheet

FyreWrap FAQ

Specification

Air Distribution System Ducts: Specifications

Submittal Sheet

FyreWrap Elite 1.5 Duct Insulation Single‑Layer Fire Rated Boiler Flue/Generator Exhaust

Technical Bulletin

Fire Protection: Fire Resistive Gypsum Shafts

Technical Bulletin

Fire Protection: Fire Rated Ducts For Air Distribution Systems

Technical Bulletin

Fire Protection: Fire Protection Duct Applications

Technical Bulletin

Fire Protection: Fire Wrap Systems as Alternative to Fire Rated Shaft Construction

Still can’t find what you’re looking for?